One partner from plan to delivery. Send your project and get a quote within 12 hours. Start a request+49 (0) 228 76383681sales@lignosupply.com
LignoSupplyRequest a quote

Home / Products / Fire-rated doors / Architects and interior designers

For architects and interior designers

Design freedom within the listing.

Rated doors do not have to look rated. We help you choose veneer, finish, glass and hardware that fit the listing before the drawings are final.

  • Veneer cuts, matching, paint-grade and laminate faces
  • Spec support for Division 08 sections
  • Submittals with listing data per opening
LABELD-H-60closer

Where design meets the listing

  • Leaf sizes and pair sizes have maximums per listing and rating
  • Vision panels: size and glass type depend on rating and wall type
  • Edge details: intumescent seals and edges must stay as listed
  • Hardware: concealed closers, pivots and electrified hardware only where listed
  • Finish: veneer species, cut and matching are free; labels must stay visible

What we provide for the spec

  • Input for sections 08 14 16 (flush wood doors), 08 71 00 (door hardware) and 08 80 00 (glazing)
  • Quality grade and duty level per WDMA I.S.1A or AWS
  • Veneer samples, finish samples and sequence-matching options
  • Submittals: listing references, cut sheets, finish samples, door elevations

Code basics

The wall decides the door.

Wall where the opening sitsTypical door ratingUsual door type
Fire walls and fire barriers, 3 to 4 hours3 hoursSteel. Wood doors are not listed at 3 hours.
Fire barriers, 2 hours (incl. shafts, exit stairways, exit passageways)90 minutesMineral core wood door
Fire barriers, 1 hour: shafts, interior exit stairways, exit passageways60 minutesMineral core wood door
Other fire barriers, 1 hour45 minutesMineral or fire-rated composite core
Fire partitions: corridor walls, 1 or 0.5 hour20 minutes + smoke and draft (S)Particleboard or composite core, gasketed
Other fire partitions, 1 hour / 0.5 hour45 / 20 minutesDepends on rating
Smoke barriers, 1 hour20 minutes + smoke and draft (S)Gasketed, self-closing, latching
Exterior walls, 2 hours / 1 hour90 / 45 minutesInterior-grade wood doors are usually not used here

Based on IBC Table 716.1(2). Ratings, vision panel limits and exceptions vary by code edition and local amendment.

Full guide to US requirements

Questions

Frequently asked.

Can a fire door have a full-height vision panel?

Only within the listing and the code limits for that wall. 20-minute doors allow larger D-20 lites; in 60 and 90-minute exit doors fire-protective glass is limited to 100 square inches.

Can rated and non-rated doors look identical?

Yes. Faces, finish and edges can match; the difference is the core, the edge seals and the label on the hinge edge.

Do you help with specs before tender?

Yes. Send the door schedule draft and we comment on ratings, sizes, glass and hardware against available listings.

Code summary for orientation, based on the International Building Code (IBC), NFPA 80, NFPA 105 and the 2010 ADA Standards. Requirements depend on the code edition your jurisdiction has adopted and on local amendments. The architect of record and the authority having jurisdiction (AHJ) decide for your project.

Related

Send us your door schedule.

Door schedule, hardware sets and elevations are enough. Answer within 12 hours, with every opening checked against the listing.

Daniel Helmut Pinger

Your contact: Daniel Helmut Pinger, Tischlermeister
+49 (0) 228 76383681 · sales@lignosupply.com

B2B requests only. We reply within 12 hours on business days. Drawings can be sent as a reply to our confirmation email.

Thank you – your request is in. Check your inbox for the confirmation; reply to it with drawings or photos.